LmCast :: Stay tuned in

A nuclear clock synchronized to 229Th

Recorded: Oct. 10, 2026, 10:01 p.m.

Original Summarized

A nuclear clock synchronized to 229Th | Nature

Skip to main content

Thank you for visiting nature.com. You are using a browser version with limited support for CSS. To obtain
the best experience, we recommend you use a more up to date browser (or turn off compatibility mode in
Internet Explorer). In the meantime, to ensure continued support, we are displaying the site without styles
and JavaScript.

Advertisement

View all journals

Saved research

Search

Log in

Content
Explore content

About the journal

Publish with us

Sign up for alerts

RSS feed

nature

articles

article

A nuclear clock synchronized to 229Th

Download PDF

Download PDF

Article

Open access

Published: 07 October 2026

A nuclear clock synchronized to 229Th
Beichen Huang1,2 na1, Gaowei Yan1,2 na1, Qi Xiao1,2 na1, Wenhao Bu 
ORCID: orcid.org/0009-0006-3098-70041,2 na1, Chengchun Zhao3,4 na1, Zhen Zhang5 na1, Chao Yan6 na1, Zhi-Ang Chen7,8, Peixiong Zhang3, Gleb Penyazkov 
ORCID: orcid.org/0000-0002-5925-62411, Zhenhai Zhan1, Lingfeng Yan 
ORCID: orcid.org/0000-0001-8965-29421, Yuefei Wang2, Lin Li3, Shanming Li3, Dapeng Jiang4, Xiaobo Qian5, Xuegang Liu9, Qiange He9, Taoxiang Sun9, Haochen Tian10,11, Bingkun Lu 
ORCID: orcid.org/0009-0003-8085-442710, Ningyuan Ma1, Juxian Li1, Yanzhang Wu1, Qiaorui Gong3,4, Yuxiang Li3,4, Haoyu Shi1, Xiangliang Li 
ORCID: orcid.org/0000-0002-7251-73462, Longsheng Ma12, Shining Zhu 
ORCID: orcid.org/0000-0002-3472-649713, Yuxiang Mo 
ORCID: orcid.org/0000-0002-8499-76231, Jun Lin6, Li You 
ORCID: orcid.org/0000-0002-3919-47681,2,11,14, Yige Lin10,11, Xibo Zhang7,8,11, Yin Hang 
ORCID: orcid.org/0000-0001-8687-17793,4, Liangbi Su 
ORCID: orcid.org/0000-0002-5792-17975 & …Shiqian Ding 
ORCID: orcid.org/0000-0002-0485-88351,2,14 Show authors

Nature
(2026) Cite this article

Save article

View saved research

13k Accesses

234 Altmetric

Metrics details

AbstractAtomic clocks have made time and frequency the most precisely measured quantities in physics, progressing from microwave standards that realize the SI second1 to optical clocks with unprecedented precision2. A nuclear clock transfers the frequency reference from an electronic to a nuclear transition and the uniquely low-lying, laser-accessible, isomeric transition in 229Th currently offers the most practical route to compact, robust timekeeping and sensitive tests of fundamental physics3,4,5,6,7,8. Realizing such a clock requires turning spectroscopy of the 229Th nuclear resonance9,10,11,12,13,14,15,16,17 into a stable discriminator for steering a traceable oscillator. Here we demonstrate a 229Th nuclear clock by stabilizing a continuous-wave, narrow-linewidth 148.4 nm vacuum-ultraviolet (VUV) laser18 to a resolved, weakly temperature-sensitive nuclear transition17,19 in 229Th:CaF2 crystals20,21,22. A 10-μW VUV source generated by four-wave mixing in cadmium vapour18,23,24 and phototube-based frequency modulation absorption readout provide a fast, high-signal-to-noise nuclear discriminator. The clock reaches a fractional frequency instability of \(5\times 1{0}^{-13}/\sqrt{\tau /{\rm{s}}}\) for averaging time τ. Clock-transition frequencies measured in two independently fabricated crystals agree at the 10−13 level and are consistent with previous VUV-comb measurements on other 229Th:CaF2 crystals17. These results establish laser-addressed nuclei as operational clock references and provide a reproducible solid-state platform for compact nuclear clocks, nuclear quantum sensors and precision tests of fundamental physics.

Similar content being viewed by others

Frequency ratio of the 229mTh nuclear isomeric transition and the 87Sr atomic clock

Article
04 September 2024

A thorium-229 optical nuclear clock with feedback loop

Article
Open access
07 October 2026

Frequency reproducibility of solid-state thorium-229 nuclear clocks

Article
28 January 2026

Explore related subjects
Discover the latest articles and news in related subjects.

Atomic and molecular physics

Quantum metrology

Optical Clock Technologies and Frequency Standards

MainLaser generation and laser spectroscopy are rooted in the electronic structure of atoms, molecules and solids. Nuclear transitions, by contrast, usually occur at energies far above typical electronic transitions, leaving most nuclear resonances beyond direct coherent access with conventional optical spectroscopy. The 229Th isomer is a singular exception. Its transition energy lies in the vacuum-ultraviolet (VUV) range, making it the only known nuclear transition that can be addressed directly with current laser technology. This coincidence opens a route to quantum coherent control of a nucleus and, in particular, to a nuclear clock, in which the frequency reference is shifted from the electronic shell to the atomic nucleus.Decades of work established the existence and energy of this low-lying state9,10,11,12,25,26,27,28,29,30,31. The observation of radiative decay from 229Th-doped crystals further showed that the isomer can remain long-lived in VUV-transparent hosts13,32,33,34,35. Building on these developments, direct laser excitation of the 229Th isomer has been achieved recently14,15,16,36, and VUV-frequency-comb spectroscopy has enabled precision measurement of the nuclear transition frequency against optical atomic clocks16. In crystalline hosts, spectroscopy has further resolved the solid-state structure of the nuclear resonance, including quadrupole-split transitions16, site-dependent shifts36,37, temperature sensitivities19 and reproducible transition frequencies across crystals17. Together with the macroscopic number of nuclei provided by a solid-state host38,39,40, these advances open the possibility of compact and field-deployable nuclear frequency references.Another enabling element for clock operation is a continuous-wave VUV source at the nuclear resonance. Resonantly enhanced four-wave mixing in metal vapour18,23,24 and randomly quasi-phase-matched SrB4O7 (refs. 41,42) have provided routes to continuous-wave 148.4-nm radiation. Converting nuclear laser spectroscopy into clock operation requires combining, in a single system, a traceable narrow-linewidth VUV probe, a 229Th-containing reference and a high-bandwidth, high-signal-to-noise readout of weak nuclear response, together with a demonstration of nuclear-transition-frequency reproducibility in independently prepared references.In this work, we develop and integrate all the ingredients required for 229Th clock operation. We upgrade the cadmium vapour four-wave-mixing source18 to generate 10 μW of continuous-wave 148.4-nm radiation with an estimated sub-Hertz linewidth. We also fabricate, in a single growth run, a compact, high-quality 229Th:CaF2 crystal from a solution containing only 1.4 μg (10 kBq) of 229Th. In fluorescence and absorption spectroscopy, we resolve a broad quadrupole-unresolved (QU) and a quadrupole-resolved (QR) structure comprising five narrow transitions, including line b, which is used for clock operation. Combining this traceable high-power VUV probe with home-grown crystals, we demonstrate the operation of the first 229Th nuclear clock by using phototube-based frequency modulation absorption spectroscopy to generate the nuclear discriminator and close a feedback loop to line b. We then use the feedback-stabilized system to characterize the clock instability and test the reproducibility of the clock-transition frequency across two independently fabricated crystals and by comparison with previous VUV-comb measurements on other 229Th:CaF2 crystals17,43.A near-simultaneous independent report has also demonstrated 229Th nuclear clock operation using the randomly quasi-phase-matched SrB4O7 VUV source, a highly doped 229Th:CaF2 crystal and photomultiplier-tube-based absorption readout44, building on related continuous-wave nuclear absorption spectroscopy with sub-nanowatt 148.4-nm light45.VUV laser for nuclear clock interrogationWe generate continuous-wave 148.4-nm radiation by resonance-enhanced four-wave mixing in cadmium vapour18,23,24. The 375-nm field is tuned to the cadmium 51S0 → 61S0 two-photon resonance, which enhances the third-order non-linear response, and a 710-nm field participates in the sum-frequency four-wave-mixing process to generate VUV radiation at 148.4 nm. The 375-nm light is generated by second-harmonic generation of a fibre-based 750-nm laser in a bow-tie enhancement cavity, delivering 5 W of ultraviolet power. Together with 10 W of 710-nm light from another fibre-based laser system, the two fundamental beams are combined and sent into a cadmium oven operated at 600 °C, where 10 μW of continuous-wave 148.4-nm radiation is generated. After the oven, the VUV light is separated spatially from the fundamental beams using a Brewster-angle MgF2 prism18 and approximately 5 μW of VUV power is delivered to the front surface of the 229Th:CaF2 crystal with a Gaussian diameter of approximately 1 mm (Fig. 1a,b).Fig. 1: Experimental platform for a solid-state 229Th nuclear clock.Full size imagea, Experimental setup. Continuous-wave 148.4-nm VUV light is generated by four-wave mixing in cadmium vapour and sent to a home-grown 229Th:CaF2 crystal. Nuclear fluorescence is collected with a PMT, and the transmitted VUV power is recorded with a phototube or a PMT. During absorption spectroscopy and clock operation, the 710-nm laser is modulated, and the transmitted VUV photocurrent is detected by lock-in demodulation. SHG, second-harmonic generation. b, Cadmium energy-level scheme for resonantly enhanced four-wave mixing. Two 375-nm photons drive the two-photon resonance between the 5 1S0 and 6 1S0 states, whereas one 710-nm photon completes the sum-frequency process to generate the 148.4-nm VUV field. c, Optical frequency chain. The 750-nm and 710-nm lasers are phase-locked to a self-referenced Er-fibre frequency comb, whose repetition rate (frep) is stabilized by a 4-km-long phase-stabilized fibre link to a cryogenic-silicon-cavity-stabilized laser at 1,397 nm. The fCEO is referenced to a hydrogen maser. d, Quadrupole-split nuclear energy levels of 229Th in a CaF2 host. Line b, a QR component corresponding to mg = ± 5/2 → mis = ± 3/2, is used for clock operation. Line c is a QR component corresponding to mg = ± 1/2 → mis = ± 1/2. e, Absorption-based clock discriminator and feedback. The lock-in-demodulated absorption signal provides a dispersive error signal near line b, and the resulting frequency correction is applied to an AOM between the 1,397-nm reference laser and the frequency comb, thereby steering the VUV frequency onto the nuclear resonance. The trace plotted shows the normalized demodulated absorption signal measured with the optimized TS1 + phototube configuration. The frequency offset is referenced to the fitted line centre, and each data point corresponds to a 10-s acquisition. The zero crossing defines the clock lock point, and the local slope converts fluctuations of the normalized demodulated signal into residual detuning for the clock servo. The frequency modulation amplitude for this trace is 12 kHz. Unless otherwise stated, all error bars throughout this work represent 1σ statistical uncertainties.The 750-nm and 710-nm lasers are phase-locked to modes of a self-referenced femtosecond Er-fibre frequency comb, whose carrier-envelope-offset frequency (fCEO), is stabilized with an f–2f interferometer to a hydrogen maser-referenced direct digital synthesizer46. The repetition rate, frep, is stabilized by locking the 1,397-nm comb branch to an ultrastable 1,397-nm laser referenced to a cryogenic silicon cavity with 10−17 level stability47. The comb therefore transfers the stability of the silicon cavity to the 710-nm and 750-nm lasers, whereas frep and fCEO are counted against the hydrogen maser to provide traceability of the VUV frequency. Under the operating conditions used for spectroscopy and clock operation, the VUV linewidth is estimated to be sub-Hertz, well below the observed inhomogeneous linewidths of the nuclear transitions in the crystal (Fig. 1c).Fabrication of 229Th:CaF2 crystalsTwo 229Th:CaF2 crystals, S1 (Fig. 2g) and TS1 (Fig. 2h), are fabricated for continuous-wave laser nuclear spectroscopy and clock operation. Both crystals are prepared as elongated cylinders, providing a long VUV interaction path and hence sufficient 229Th column density for absorption readout. S1 is grown at the Shanghai Institute of Optics and Fine Mechanics using the Bridgman–Stockbarger method, with medium-frequency induction heating. S1 has a diameter of 1.44 mm, a length of 9.8 mm and an average 229Th concentration of 9.7 × 1016 cm−3. The crystal contains small bubbles along its central axis (Fig. 2g) and has a VUV transmission of approximately 1%. The limited VUV transmission and 229Th concentration, together with the small fraction of incorporated nuclei occupying the QR site36, reduce the signal-to-noise ratio (SNR) of the absorption discriminator. Nevertheless, S1 still supports fluorescence spectroscopy, absorption spectroscopy and initial nuclear clock operation.Fig. 2: Fluorescence and absorption spectroscopy of 229Th:CaF2 crystals.Full size imagea, Spectral overview of the nuclear transitions measured in TS1 on an absolute VUV-frequency axis. The fitted QR and QU profiles are shown, with all data points normalized to the maximum measured signal in the spectrum. b, Expanded, normalized fluorescence excitation spectra of line b (left, blue), QU (centre, grey) and line c (right, orange) from a. c, Frequency modulation absorption signals of the same three spectral components measured with an analogue-current PMT readout in S1. Each data point is acquired for 80 s. d, Corresponding absorption signals measured with the phototube in S1. Each data point is acquired for 40 s. e, Absorption signals measured with the phototube in TS1. Each data point is acquired for 10 s. In b–e, the frequency offset is referenced to the fitted centre of each spectral component, and the signals are normalized. Separate fine absorption scans across QU, performed with reduced modulation amplitudes, reveal no reproducible narrow features on frequency scales of approximately 500 Hz or larger. f, Time-resolved nuclear fluorescence decay measured in TS1 following VUV excitation on QU, fitted with a single-exponential decay. g, S1 crystal. h, TS1 crystal. i,j, Calculated depth-dependent steady-state excitation fraction, ps(z), for resonant excitation through line b (blue), QU (grey) and line c (orange) in S1 (i) and TS1 (j). Here z is measured from the VUV entrance surface. The calculation uses the transition line strengths, measured ensemble linewidths and nuclear lifetime, together with the local VUV photon flux after accounting for surface reflection and off-resonant propagation loss through the crystal (Methods). a.u., arbitrary units.To address these limitations and test the reproducibility of the clock-transition frequency across crystals, TS1 is fabricated using the temperature-gradient technique22 through a collaboration between the Shanghai Institute of Ceramics of Chinese Academy of Sciences and Tsinghua University. This method employs a vertical temperature gradient, as in Bridgman–Stockbarger growth, but keeps the crucible stationary. Crystallization is driven by gradually lowering the temperature of the graphite heater, rather than by translating the crucible, with a cooling rate of 2 °C h−1 and a pressure below 1 × 10−3 Pa.Using this approach, we fabricate TS1 from a growth solution containing only 1.4 μg (10 kBq) of 229Th. The small isotope amount, dictated by the severe scarcity of 229Th, leaves essentially no room for iterative growth optimization. The resulting bubble-free TS1 crystal has a diameter of 1.09 mm, a length of 4.94 mm, an average 229Th concentration of 2.2 × 1017 cm−3, and a VUV transmission of 7%.Continuous-wave fluorescence spectroscopyWe perform continuous-wave fluorescence spectroscopy on both S1 and TS1. At each frequency point, the crystal is illuminated with the VUV laser for 400 s, during which the transmitted VUV power is monitored simultaneously by the phototube. The 148-nm nuclear fluorescence is then recorded with the photomultiplier tube (PMT) for 200 s. The fluorescence-signal analysis accounts for variations in the excitation power and for residual population from preceding measurements due to the comparable nuclear excited-state lifetime and measurement-cycle duration (Methods). Both crystals exhibit a broad QU structure, consistent with a small effective electric-field gradient36, together with a QR manifold in which the nuclear transition is split into five narrow components16,36 (Fig. 1d). The spectra shown in Fig. 2a,b are recorded in TS1.Within the QR manifold, the mg = ± 5/2 → mis = ± 3/2 and mg = ± 1/2 → mis = ± 1/2 transitions are labelled lines b and c, respectively, following ref. 16. In TS1, lines b and c have fitted full-width at half-maximum (FWHM) values of 27(1) kHz and 39(2) kHz, respectively, consistent with those previously reported for low-229Th-concentration crystals17 (Fig. 2b; Methods). For the QU structure, the fitted linewidth is 0.898(5) MHz. Following resonant excitation of QU, we record the subsequent fluorescence decay and obtain an excited-state lifetime of 631(2) s from a single-exponential fit (Fig. 2f).Absorption spectroscopyTo obtain a rapid spectroscopic readout of the long-lived nuclear excitation, we monitor the VUV power transmitted through the crystal and measure the nuclear response in absorption. Because the on-resonance fractional absorption of the VUV light is small (approximately 10−4), we modulate the VUV frequency sinusoidally and demodulate the transmitted VUV signal to extract the absorption-induced response. Normalizing the demodulated signal to the simultaneously recorded direct current transmission produces a dispersive-like signal (Fig. 1e), which is used as the frequency discriminator for clock operation. Fitting the full frequency-modulated line shape yields the linewidth of the underlying nuclear transition and its on-resonance fractional absorption of the VUV light (Methods).We characterize the absorption readout performance by the 1-s absorption SNR, defined as the peak of the normalized demodulated absorption signal relative to the baseline noise projected to a 1-s measurement time (Methods). In the photon-shot-noise limit, the 1-s absorption SNR scales as \({{\rm{S}}{\rm{N}}{\rm{R}}}_{1{\rm{s}}}\propto A{[{\mathop{N}\limits^{.}}_{e}\cdot (1{\rm{s}})]}^{1/2}\), where A is the on-resonance fractional VUV absorption and \({\mathop{N}\limits^{.}}_{e}\) is the detected photoelectron rate (Methods). This scaling motivates the successive optimization of the photodetection scheme and crystal properties described below.We first perform absorption spectroscopy on S1 using a PMT operated in analogue-current mode (Fig. 2c). Lines b and c, together with QU, are resolved after sufficiently long measurement times. Although dynode multiplication provides sufficient gain for detecting the weak absorption signal, PMT saturation limits the VUV power reaching the detector to approximately 3 nW. The resulting low detected photoelectron rate leads to a large relative photon-shot-noise, limiting the 1-s absorption SNR.We next replace the PMT with a phototube operated in direct-photocurrent mode, which accommodates substantially greater VUV power without saturation. The photocurrent is amplified with a low-noise transimpedance amplifier, enabling a higher detected photoelectron rate without a substantial electronic-noise penalty. With S1 unchanged, this detector upgrade improves the 1-s absorption SNR (Fig. 2d).In the third stage, we retain the phototube readout and replace S1 with TS1. The higher VUV transmission of TS1 increases the transmitted VUV power to approximately 200 nW and the detected photoelectron rate by approximately 30-fold relative to the S1 + PMT configuration, after correcting for detector quantum efficiencies. Together with the approximately threefold larger measured b-line fractional absorption in TS1, this raises the b-line 1-s absorption SNR to approximately 20 times that obtained with the S1 + PMT configuration (Fig. 2e).The increase in 1-s absorption SNR across the three configurations allows the laser detuning from the nuclear resonance to be determined more precisely. We next use the normalized demodulated absorption signal in each configuration for nuclear clock operation and observe a corresponding improvement in the fractional frequency instability.Nuclear clock operation and instabilityWe operate the nuclear clock by locking the comb-referenced 148.4-nm VUV laser to line b, which combines a narrow linewidth with weak temperature sensitivity17,19. In each interrogation cycle, the normalized demodulated absorption signal is converted to a residual detuning using the calibrated discriminator slope. This detuning is fed back through an acousto-optic modulator (AOM) in the comb-referenced optical chain (Fig. 1c) to update the VUV interrogation frequency for the next cycle. The resulting cycle-by-cycle VUV frequency record is used to calculate the in-loop fractional frequency instability shown in Fig. 3. Between nuclear interrogations, the VUV laser inherits the stability of the cryogenic-silicon-cavity-stabilized optical reference through the comb-referenced optical chain. The independently characterized fractional instability of this reference remains below 10−15 at 1,000 s, well below the measured nuclear clock instability at comparable averaging times47. This supports using the in-loop record as a faithful estimate of the instability of the operating nuclear clock.Fig. 3: Fractional frequency instability of the nuclear clock.Full size imageOverlapping Allan deviations measured for four configurations: S1 + PMT, S1 + phototube, TS1 + phototube and optimized TS1 + phototube. Dashed lines, weighted τ−1/2 fits. Error bars, 68.3% confidence intervals calculated from the equivalent degrees of freedom of the overlapping Allan deviation estimator under the assumed white-frequency-noise model. The modulation frequencies, modulation amplitudes, lock-in time constants, measurement times and feedback-cycle durations used for the four instability measurements are summarized in Extended Data Table 1.Using this interrogation-and-feedback scheme, the three absorption readout configurations described above yield progressively improved clock instability (Fig. 3). The fitted fractional frequency instabilities decrease from \(1\times 1{0}^{-11}/\sqrt{\tau /{\rm{s}}}\) for S1 + PMT to \(6\times 1{0}^{-12}/\sqrt{\tau /{\rm{s}}}\) for S1 + phototube and \(2\times 1{0}^{-12}/\sqrt{\tau /{\rm{s}}}\) for TS1 + phototube before further optimization.We then optimize the TS1 + phototube configuration by increasing the average transmitted VUV power to 350 nW, increasing the measurement duty cycle to approximately 85%, reducing residual amplitude modulation and using a near-optimal modulation amplitude of 12 kHz (Fig. 1e and Extended Data Table 1; Methods). The remaining 15% dead time arises from technical overhead in the present digital-feedback implementation and could be reduced substantially through improved feedback control. The overlapping Allan deviation is statistically consistent with τ−1/2 scaling over the measured interval, with a fitted instability of $${\sigma }_{y}(\tau )=5\times 1{0}^{-13}/\sqrt{\tau /{\rm{s}}}.$$
(1)
This instability is within a factor of two of the photon-shot-noise limit calculated from the measured absorption discriminator parameters (Methods).In all four configurations, the crystal temperature and magnetic field are controlled to limit the systematic shifts and resulting frequency fluctuations, which affect the inter-crystal frequency comparisons and clock instability, respectively. The measured crystal temperature is 301.4(1) K, with a systematic standard uncertainty of 0.1 K dominated by the temperature-sensor calibration. For line b, the root-mean-square temporal temperature fluctuation of 3 mK corresponds to a frequency fluctuation of approximately 6 Hz, or a fractional frequency fluctuation of approximately 3 × 10−15 (refs. 17,19). The ambient magnetic field is suppressed by multilayer μ-metal shielding, and a bifilar heater winding and twisted current leads minimize additional current-induced fields. The residual magnetic field is estimated by simulation to be approximately 1 mG, corresponding to an estimated Zeeman contribution below 1 Hz17,48.To test the inter-crystal reproducibility of the clock transition, we compare the centre frequencies of line b in S1 and TS1, obtaining νb,S1 = 2,020,407,298,798.077(63)stat(185)sys kHz and νb,TS1 = 2,020,407,298,798.635(20)stat(185)sys kHz, respectively (Methods). For this inter-crystal comparison, the relevant temperature contribution is set by the residual relative-temperature uncertainty. Combining this contribution with the statistical line centre uncertainties, we obtain an inter-crystal frequency difference of 5.6(13) × 102 Hz, corresponding to a fractional frequency difference of 2.8(6) × 10−13.For an inter-laboratory comparison, we evaluate the quadratic fit to the published JILA C10 and C13 b-line data17 at 301.4(1) K, obtaining an inferred frequency of νb,JILA = 2,020,407,298,798.58(122) kHz, where the uncertainty is a combined standard uncertainty dominated by the JILA temperature-dependent fit (Methods). The frequency offsets of S1 and TS1 relative to this inferred JILA value are −0.50(122) kHz and +0.06(122) kHz, respectively, both consistent with zero within the combined standard uncertainties. These comparisons therefore provide a quantitative assessment of the b-line frequency reproducibility across independently fabricated crystals and independent experimental platforms.ConclusionWe perform continuous-wave laser spectroscopy of the 229Th isomeric transition in home-grown 229Th:CaF2 crystals and resolve both QU and QR in fluorescence and absorption spectroscopy. We demonstrate an operating nuclear clock based on high-bandwidth, high-SNR phototube absorption readout. The phototube detection is compatible with substantially higher transmitted VUV power than PMT readout, thereby overcoming the photon flux bottleneck and enabling robust absorption locking. The clock reaches a fractional frequency instability of \(5\times 1{0}^{-13}/\sqrt{\tau /{\rm{s}}}\), averaging down to the 10−15 level over the measured interval. Temperature fluctuations and the residual Zeeman contribution are below the present instability limit. Together with the crystal-to-crystal agreement of the clock-transition frequency, these results establish laser-addressed nuclei as operational clock references and 229Th:CaF2 as a stable, reproducible solid-state platform for compact nuclear clocks.MethodsFluorescence-signal analysisThe fluorescence spectra of S1 and TS1 were obtained by correcting for two effects in the measured fluorescence signals. Residual excited-state population from preceding measurements was removed using a procedure adapted from refs. 14,17, whereas variations in the excitation were corrected using the monitored transmitted VUV power during each excitation interval.For each spectrum, the fluorescence records from all frequency points i are fitted jointly to $${C}_{i}(t)=B+{A}_{i}\exp (-t/{\tau }_{e}),$$
(2)
where t is measured from the beginning of the acquisition window, Ai is the fluorescence amplitude at the beginning of that window and B is a common constant background count rate for the corresponding spectrum. The lifetime is fixed to the independently measured value τe = 631 s.Because fluorescence acquisition of each frequency point begins before the residual excited-state population from previous acquisitions has decayed fully, the measured fluorescence records contain contributions from earlier excitations. The net fluorescence amplitude at each frequency point is therefore obtained by subtracting the preceding-point amplitude extrapolated to the start of the current fluorescence acquisition window: $${A}_{i,{\rm{net}}}={A}_{i}-{A}_{i-1}\exp \,\left[-\frac{{t}_{i,\det }-{t}_{i-1,\det }}{{\tau }_{e}}\right],$$
(3)
where \({t}_{i,\det }\) and \({t}_{i-1,\det }\) are the start times of the fluorescence acquisition windows of the current and previous frequency points, respectively.To correct for variations in the excitation arising from VUV power fluctuations, the transmitted VUV power is monitored during each excitation interval. In the weak-excitation regime, the excited-state population generated during an infinitesimal excitation interval of dt is proportional to the instantaneous transmitted VUV power P(t), whereas population excited at an earlier time is reduced by spontaneous decay before the fluorescence acquisition window48,49. The effective excitation dose for the frequency point i is therefore $${D}_{i}={\int }_{{t}_{i,{\rm{on}}}}^{{t}_{i,{\rm{off}}}}P(t)\exp \,\left[-\frac{{t}_{i,\det }-t}{{\tau }_{e}}\right]dt,$$
(4)
where ti,on and ti,off denote the start and end of the excitation interval of frequency point i.The net fluorescence amplitude is then normalized to the effective excitation dose to obtain a corrected fluorescence response: $${F}_{i}=\frac{{A}_{i,{\rm{net}}}}{{D}_{i}}.$$
(5)
This normalization makes the corrected fluorescence response insensitive to the frequency point acquisition order and variations in the VUV excitation.The corrected fluorescence responses Fi constitute the fluorescence spectrum for each spectral component s. The spectrum is fitted to a single-Lorentzian profile $${F}_{s}(\nu )={F}_{0,s}+\frac{{H}_{s}}{1+4{[(\nu -{\nu }_{0,s})/\Delta {\nu }_{s}]}^{2}},$$
(6)
where F0,s is the constant offset, Hs is the Lorentzian peak height, ν0,s is the line-centre frequency and Δνs is the FWHM. Applying this Lorentzian fit to TS1 yields linewidths of Δνb = 27(1) kHz, Δνc = 39(2) kHz and ΔνQU = 0.898(5) MHz.For the narrow QR transitions, the spectra of lines a–d in both S1 and TS1 show evidence of a broad pedestal in addition to the narrow central component. A representative example, line b in TS1, is shown in Extended Data Fig. 1. The pedestal could reflect an inhomogeneously broadened subensemble of QR sites, arising from variations in the local fluoride environment, lattice strain or nearby defects, although its microscopic origin remains to be established.Absorption signal analysisTo extract transition linewidths and on-resonance fractional absorptions, we fit the demodulated absorption signals to the first-harmonic response of a sinusoidally frequency-modulated Lorentzian line shape.For each spectral component s ∈ {b, c, QU}, the measured normalized demodulated absorption signal is $${S}_{1f,s}^{{\rm{RMS}}}(\bar{\nu })\equiv \frac{{V}_{1f,s}^{{\rm{RMS}}}(\bar{\nu })}{{V}_{{\rm{DC}}}(\bar{\nu })},$$
(7)
where \({V}_{1f,s}^{{\rm{RMS}}}(\bar{\nu })\) is the in-phase first-harmonic voltage recorded by the lock-in amplifier in the root-mean-square units and \({V}_{{\rm{DC}}}(\bar{\nu })\) is the direct current signal of the simultaneously monitored transmitted VUV light.The normalized demodulated absorption signal is modelled as $${S}_{1f,s}^{{\rm{RMS}}}(\bar{\nu })=\frac{1}{\sqrt{2}}{A}_{s}{{\mathcal{D}}}_{s}(\bar{\nu })+{E}_{s},$$
(8)
where As ≡ (Poff − Pon,s)/Poff is the on-resonance fractional absorption of the VUV light, with Poff the off-resonant transmitted power and Pon,s the transmitted power at the centre of spectral component s without frequency modulation. Es is a fitted constant offset. The function \({{\mathcal{D}}}_{s}(\bar{\nu })\) is the first-harmonic response function for a unit-height Lorentzian absorption profile \({{\mathcal{L}}}_{s}(\nu )\), $${{\mathcal{D}}}_{s}(\bar{\nu })=\frac{1}{{\rm{\pi }}}{\int }_{0}^{2{\rm{\pi }}}{{\mathcal{L}}}_{s}(\bar{\nu }+{\delta }_{s}\cos \theta )\cos \theta \,d\theta ,$$
(9)
where $${{\mathcal{L}}}_{s}(\nu )={\left[1+4{\left(\frac{\nu -{\nu }_{0,s}}{\Delta {\nu }_{s}}\right)}^{2}\right]}^{-1}.$$
(10)
Here \(\bar{\nu }\) is the mean laser frequency, δs is the modulation amplitude, θ is the modulation phase, ν0,s is the line-centre frequency and Δνs is the Lorentzian FWHM. Fits of (8) to the measured normalized demodulated signals yield the on-resonance fractional absorptions As and transition linewidths Δνs.The 1-s absorption SNR in the main text is defined as the peak amplitude of the normalized demodulated absorption signal divided by the s.d. of the signal baseline projected to a 1-s measurement time: $${{\rm{SNR}}}_{1{\rm{s}}}\equiv \frac{{\max }_{\bar{\nu }}| {S}_{1f,s}^{{\rm{RMS}}}| }{{\sigma }_{1{\rm{s}}}[{S}_{1f,s}^{{\rm{RMS}}}]}.$$
(11)
In the photon-shot-noise limit, it reduces to $$\begin{array}{l}{{\rm{SNR}}}_{1{\rm{s,SN}}}\,\simeq \frac{{A}_{s}{\max }_{\bar{\nu }}| {{\mathcal{D}}}_{s}(\bar{\nu })| /\sqrt{2}}{\sqrt{1/[\mathop{{N}_{e}}\limits^{.}\cdot (1\,{\rm{s}})]}}\\ \,=\,{k}_{s}\,{A}_{s}\sqrt{{\mathop{N}\limits^{.}}_{e}\cdot (1\,{\rm{s}})},\end{array}$$
(12)
where \(\mathop{{N}_{e}}\limits^{.}\) is the detected photoelectron rate and \({k}_{s}=\frac{1}{\sqrt{2}}{\max }_{\bar{\nu }}| {{\mathcal{D}}}_{s}(\bar{\nu })| \) is the proportionality factor for the spectral component s. The dependence of the \({{\rm{SNR}}}_{1{\rm{s,SN}}}\) on both As and \({\mathop{N}\limits^{.}}_{e}\) motivates the successive improvements to the detector and crystal used in absorption spectroscopy and clock operation.Resonant steady-state excitation fractionTo quantify the resonant nuclear excitation throughout the crystal, we calculate the depth-dependent steady-state excitation fraction ps(z) for the laser tuned to the centre of each spectral component, s ∈ {b, c, QU}, following ref. 49. In the weak-excitation regime, $${p}_{s}(z)={\Gamma }_{{\rm{exc}}}^{(s)}(z){\tau }_{e},$$
(13)
where \({\Gamma }_{{\rm{exc}}}^{(s)}(z)\) is the excitation rate and τe is the measured nuclear lifetime.The Rabi frequency for component s is $${\Omega }_{s}(z)={\left[\frac{2{\rm{\pi }}{c}^{2}I(z){\chi }_{s}{\Gamma }_{\gamma }}{\hbar {\omega }_{0}^{3}}\right]}^{1/2},$$
(14)
where I(z) is the local VUV intensity, ω0 is the angular nuclear-transition frequency, Γγ ≃ 2π × 63 μHz is the radiative decay rate calculated from the measured excited-state lifetime and χs is the effective line-strength factor. For s = b, c and QU, the effective line-strength factors are, respectively, $$({\chi }_{b},{\chi }_{c},{\chi }_{{\rm{QU}}})=\left(\frac{2}{9},\frac{1}{5},\frac{2}{3}\right).$$
(15)
These values are obtained by summing the squared Clebsch–Gordan coefficients over the unresolved magnetic-sublevel transitions and averaging the resulting coupling strengths over the orientations of the effective quantization axes relative to the laser polarization48.Because resonant nuclear absorption is negligible compared with the off-resonant propagation loss, the local VUV intensity is approximated as $$I(z)\simeq \frac{{P}_{{\rm{in}}}(1-R)}{{S}_{{\rm{beam}}}}\exp (-{\alpha }_{{\rm{nr}}}z),$$
(16)
where Pin is the incident VUV power and Sbeam is the effective illuminated area. The Fresnel reflectance and effective off-resonant attenuation coefficient are $$\begin{array}{l}\,R\,=\,{\left(\frac{n-1}{n+1}\right)}^{2},\\ {\alpha }_{{\rm{nr}}}\,=\,-\frac{1}{L}\text{ln}\,\left[\frac{{T}_{{\rm{xtal}}}}{{(1-R)}^{2}}\right],\end{array}$$
(17)
where n is the refractive index of CaF2, L is the crystal length and Txtal is the measured off-resonant transmission through the crystal. For S1 and TS1, Txtal is approximately 1% over 9.8 mm and 7% over 4.94 mm, corresponding to equivalent 1-mm internal transmittances of 63% and 60%, respectively.For a spectral component with measured FWHM Δνs, the resonant excitation rate in the weak-excitation regime is49:$${\Gamma }_{{\rm{exc}}}^{(s)}(z)=\frac{{\Omega }_{s}^{2}(z)}{2{\rm{\pi }}\Delta {\nu }_{s}},$$
(18)
giving $${p}_{s}(z)=\frac{{\Omega }_{s}^{2}(z){\tau }_{e}}{2{\rm{\pi }}\Delta {\nu }_{s}}.$$
(19)
Using an incident VUV power of approximately 5 μW with a Gaussian-beam 1/e2  intensity diameter of approximately 1 mm, together with the measured linewidths and off-resonant transmissions of S1 and TS1, we evaluate ps(z) for the b, c and QU components throughout each crystal. The resulting depth-dependent excitation fractions are shown in Fig. 2i,j.For the present experimental parameters, the entrance surface Rabi frequencies are Ωs < 2π × 1 Hz, more than two orders of magnitude smaller than both the crystal-induced optical-decoherence rates and the magnetic-sublevel-mixing rates, which are of order 2π × 102 Hz4,48. This hierarchy justifies the excitation rate treatment used above, with the measured ensemble linewidth Δνs providing the effective linewidth of each spectral component.Frequency discriminator optimizationTo minimize the measurement-noise contribution to the fractional frequency instability of the nuclear clock, we optimize the modulation amplitude to maximize the slope of the frequency discriminator at the centre of line b. Following the standard stability analysis for atomic clocks2, the fractional frequency instability arising from statistically independent cycle-to-cycle measurement noise is $${\sigma }_{y}(\tau )=\frac{{\sigma }_{S}}{{\nu }_{0}\,{g}_{b}}{\left(\frac{{T}_{{\rm{c}}}}{\tau }\right)}^{1/2},$$
(20)
where σS is the fluctuation of the normalized demodulated absorption signal at the line centre, ν0 is the nuclear-transition frequency, Tc is the clock-cycle duration, τ is the averaging time and $${g}_{b}\equiv {\left|\frac{\partial {S}_{1f,b}^{{\rm{RMS}}}(\bar{\nu })}{\partial \bar{\nu }}\right|}_{\bar{\nu }={\nu }_{0,b}}=\frac{{A}_{b}}{\sqrt{2}}{\left|\frac{\partial {{\mathcal{D}}}_{b}(\bar{\nu })}{\partial \bar{\nu }}\right|}_{\bar{\nu }={\nu }_{0,b}}$$
(21)
is the magnitude of the discriminator slope at the line centre. Provided that σS is approximately independent of the modulation amplitude over the relevant range, maximizing gb minimizes the corresponding contribution to the clock instability.For a Lorentzian line with FWHM Δνb and peak modulation amplitude δb, the discriminator slope is $${g}_{b}={A}_{b}\frac{4\sqrt{2}{\delta }_{b}}{\Delta {\nu }_{b}^{2}}{\left[1+4{\left(\frac{{\delta }_{b}}{\Delta {\nu }_{b}}\right)}^{2}\right]}^{-3/2}.$$
(22)
Maximizing gb with respect to δb gives $${\delta }_{b,{\rm{opt}}}=\frac{\Delta {\nu }_{b}}{2\sqrt{2}}.$$
(23)
For the measured b-line linewidth Δνb = 27(1)kHz, the modulation amplitude that maximizes the line-centre discriminator slope is δb,opt ≃ 9.5 kHz. A slightly larger modulation amplitude provides a wider monotonic frequency discrimination range and hence greater tolerance to frequency excursions during feedback operation. We therefore use a near-optimal δb = 12 kHz, which increases the width of the monotonic frequency discrimination range by approximately 13% while retaining 96.4% of the maximum line-centre slope. At this modulation amplitude, the discriminator slope is $${g}_{b}=1.05{A}_{b}/\Delta {\nu }_{b}.$$
(24)
Clock instability at photon-shot-noise limitWe estimate the photon-shot-noise-limited fractional frequency instability of the optimized TS1 + phototube configuration from the detected VUV power. The detected photoelectron rate is \({\mathop{N}\limits^{.}}_{e}={\eta }_{\det }{P}_{\det }/(h{\nu }_{0})\), where \({P}_{\det }\) is the detected VUV power and \({\eta }_{\det }\) is the phototube quantum efficiency. For a measurement time Tm, the photon-shot-noise-limited s.d. of the normalized demodulated absorption signal is50$${\sigma }_{S,{\rm{SN}}}={\left(\frac{1}{{\mathop{N}\limits^{.}}_{e}{T}_{{\rm{m}}}}\right)}^{1/2}.$$
(25)
Substituting this expression into (20) and using the near-optimized discriminator slope gb = 1.05Ab/Δνb gives $${\sigma }_{y}(\tau )=\frac{\Delta {\nu }_{b}}{1.05\,{\nu }_{0}\,{A}_{b}}{\left(\frac{h{\nu }_{0}}{{\eta }_{\det }{P}_{\det }\tau }\right)}^{1/2}{\left(\frac{{T}_{{\rm{c}}}}{{T}_{{\rm{m}}}}\right)}^{1/2}.$$
(26)
For the optimized TS1 + phototube configuration, we use \({P}_{\det }=350\,{\rm{nW}}\), \({\eta }_{\det }\simeq 0.10\), Ab = 2.9 × 10−4, Δνb = 27 kHz, Tm = 10.0s and Tc = 11.8s, yielding $${\sigma }_{y}(\tau )\simeq 2.9\times 1{0}^{-13}/\sqrt{\tau /{\rm{s}}}.$$
(27)
The measured instability of \(5\times 1{0}^{-13}/\sqrt{\tau /{\rm{s}}}\) is within a factor of two of this limit, indicating near-photon-shot-noise-limited operation. The remaining difference can be accounted for partly by the gradual decrease in detected VUV power during the measurement.Absolute-frequency determinationFor the absolute-frequency measurements of line b in S1 and TS1 at a crystal temperature of 301.4(1) K, the VUV laser is stabilized to the centre of the corresponding absorption resonance. The locked VUV frequency is determined through the comb-referenced optical chain used for VUV generation, including the comb mode numbers, optical beat notes, AOM shifts and fixed RF offsets. All RF synthesizers and frequency counters are referenced to a common 10-MHz hydrogen maser signal. The reconstructed frequency is corrected for the fractional frequency offset of the hydrogen maser relative to International Atomic Time, using the monthly International Atomic Time clock-rate data for the corresponding measurement periods.The resulting b-line centre frequencies are $$\begin{array}{l}{\nu }_{b,{\rm{S1}}}\,=\,\mathrm{2,020,407,298,798.077}{(63)}_{{\rm{stat}}}{(185)}_{{\rm{sys}}}\,{\rm{kHz}},\\ {\nu }_{b,{\rm{TS1}}}\,=\,\mathrm{2,020,407,298,798.635}{(20)}_{{\rm{stat}}}{(185)}_{{\rm{sys}}}\,{\rm{kHz}}.\end{array}$$
(28)
The first set of parentheses gives the 1σ statistical uncertainty, and the second gives the systematic uncertainty. These systematic uncertainties arise from the 0.1 K absolute crystal temperature uncertainty, dominated by the sensor calibration, propagated through the local temperature coefficient of line b reported in ref. 17.Inter-laboratory frequency comparisonFor comparison with the JILA measurements, we fit the publicly available C10 and C13 source data43 using the quadratic temperature-dependence model reported in ref. 17. Evaluating the fit at our crystal temperature of 301.4(1) K yields $${\nu }_{b,{\rm{JILA}}}\,=\,\mathrm{2,020,407,298,798.58}(122)\,{\rm{kHz}},$$
(29)
where the 1σ uncertainty combines in quadrature the 1.21 kHz fit uncertainty and the 0.185 kHz contribution from the uncertainty of our crystal temperature.The offsets of the S1 and TS1 measurements from the JILA value are $$\begin{array}{l}\,{\nu }_{b,{\rm{S1}}}-{\nu }_{b,{\rm{JILA}}}\,=\,-0.50(122)\,{\rm{kHz}},\\ {\nu }_{b,{\rm{TS1}}}-{\nu }_{b,{\rm{JILA}}}\,=\,+0.06(122)\,{\rm{kHz}}.\end{array}$$
(30)
The agreement within the combined standard uncertainties verifies the reproducibility of the b-line frequency across independently fabricated crystals and independent experimental platforms.

Data availability
The datasets generated and analysed during this study are available at Figshare (https://doi.org/10.6084/m9.figshare.33386191)51.
Code availability
The plotting scripts used to generate the figures are available at Figshare (https://doi.org/10.6084/m9.figshare.33386191)51.
ReferencesEssen, L. & Parry, J. V. An atomic standard of frequency and time interval: a caesium resonator. Nature 176, 280–282 (1955).Article 
ADS 

Google Scholar 
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E. & Schmidt, P. O. Optical atomic clocks. Rev. Mod. Phys. 87, 637–701 (2015).Article 
ADS 
CAS 

Google Scholar 
Peik, E. & Tamm, C. Nuclear laser spectroscopy of the 3.5 eV transition in Th-229. Europhys. Lett. 61, 181 (2003).Article 
ADS 
CAS 

Google Scholar 
Rellergert, W. G. et al. Constraining the evolution of the fundamental constants with a solid-state optical frequency reference based on the 229Th nucleus. Phys. Rev. Lett. 104, 200802 (2010).Article 
ADS 
PubMed 

Google Scholar 
Campbell, C. J. et al. Single-ion nuclear clock for metrology at the 19th decimal place. Phys. Rev. Lett. 108, 120802 (2012).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Flambaum, V. V. Enhanced effect of temporal variation of the fine structure constant and the strong interaction in 229Th. Phys. Rev. Lett. 97, 092502 (2006).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Beeks, K. et al. Fine-structure constant sensitivity of the Th-229 nuclear clock transition. Nat. Commun. 16, 9147 (2025).Article 
ADS 
CAS 
PubMed 
PubMed Central 

Google Scholar 
Peik, E. et al. Nuclear clocks for testing fundamental physics. Quantum Sci. Technol. 6, 034002 (2021).Article 
ADS 

Google Scholar 
von der Wense, L. et al. Direct detection of the 229Th nuclear clock transition. Nature 533, 47–51 (2016).Article 
ADS 
PubMed 

Google Scholar 
Seiferle, B. et al. Energy of the 229Th nuclear clock transition. Nature 573, 243–246 (2019).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Masuda, T. et al. X-ray pumping of the 229Th nuclear clock isomer. Nature 573, 238–242 (2019).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Sikorsky, T. et al. Measurement of the 229Th isomer energy with a magnetic microcalorimeter. Phys. Rev. Lett. 125, 142503 (2020).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Kraemer, S. et al. Observation of the radiative decay of the 229Th nuclear clock isomer. Nature 617, 706–710 (2023).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Tiedau, J. et al. Laser excitation of the Th-229 nucleus. Phys. Rev. Lett. 132, 182501 (2024).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Elwell, R. et al. Laser excitation of the 229Th nuclear isomeric transition in a solid-state host. Phys. Rev. Lett. 133, 013201 (2024).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Zhang, C. et al. Frequency ratio of the 229mTh nuclear isomeric transition and the 87Sr atomic clock. Nature 633, 63–70 (2024).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Ooi, T. et al. Frequency reproducibility of solid-state thorium-229 nuclear clocks. Nature 650, 72–78 (2026).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Xiao, Q. et al. Continuous-wave narrow-linewidth vacuum ultraviolet laser source. Nature 650, 852–856 (2026).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Higgins, J. S. et al. Temperature sensitivity of a thorium-229 solid-state nuclear clock. Phys. Rev. Lett. 134, 113801 (2025).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Beeks, K. et al. Growth and characterization of thorium-doped calcium fluoride single crystals. Sci. Rep. 13, 3897 (2023).Article 
ADS 
CAS 
PubMed 
PubMed Central 

Google Scholar 
Gong, Q. et al. Structures and properties of high-concentration doped Th:CaF2 single crystals for solid-state nuclear clock materials. Inorg. Chem. 63, 3807–3814 (2024).Article 
CAS 
PubMed 

Google Scholar 
Su, L. et al. Growth, characterization and optical quality of CaF2 single crystals grown by the temperature gradient technique. Mater. Res. Bull. 40, 619–628 (2005).Article 
CAS 

Google Scholar 
Xiao, Q. et al. Proposal for the generation of continuous-wave vacuum-ultraviolet laser light for Th-229 isomer precision spectroscopy. Phys. Rev. Appl. 25, 024034 (2026).Article 
ADS 
CAS 

Google Scholar 
Penyazkov, G., Yu, Y., Skripnikov, L. V. & Ding, S. Theoretical study of transition matrix elements in cadmium for vacuum-ultraviolet generation in 229Th nuclear clock applications. Phys. Rev. A 112, 022807 (2025).Article 
ADS 
CAS 

Google Scholar 
Kroger, L. & Reich, C. Features of the low-energy level scheme of 229Th as observed in the α-decay of 233U. Nucl. Phys. A 259, 29–60 (1976).Article 
ADS 

Google Scholar 
Reich, C. & Helmer, R. Energy separation of the doublet of intrinsic states at the ground state of 229Th. Phys. Rev. Lett. 64, 271 (1990).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Helmer, R. & Reich, C. An excited state of 229Th at 3.5 eV. Phys. Rev. C 49, 1845 (1994).Article 
ADS 
CAS 

Google Scholar 
Beck, B. et al. Energy splitting of the ground-state doublet in the nucleus 229Th. Phys. Rev. Lett. 98, 142501 (2007).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Thielking, J. et al. Laser spectroscopic characterization of the nuclear-clock isomer 229mTh. Nature 556, 321–325 (2018).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Yamaguchi, A. et al. Laser spectroscopy of triply charged 229Th isomer for a nuclear clock. Nature 629, 62–66 (2024).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Beeks, K. et al. The thorium-229 low-energy isomer and the nuclear clock. Nat. Rev. Phys. 3, 238–248 (2021).Article 
CAS 

Google Scholar 
Hiraki, T. et al. Controlling 229Th isomeric state population in a VUV transparent crystal. Nat. Commun. 15, 5536 (2024).Article 
ADS 
CAS 
PubMed 
PubMed Central 

Google Scholar 
Schaden, F. et al. Laser-induced quenching of the Th-229 nuclear clock isomer in calcium fluoride. Phys. Rev. Res. 7, L022036 (2025).Article 
CAS 

Google Scholar 
Terhune, J. et al. Photo-induced quenching of the 229Th isomer in a solid-state host. Phys. Rev. Res. 7, L022062 (2025).Article 
CAS 

Google Scholar 
Guan, M. et al. X-ray-induced quenching of the 229Th clock isomer in CaF2. Phys. Rev. Lett. 136, 013203 (2026).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Hiraki, T. et al. Laser Mössbauer spectroscopy of 229Th in CaF2. Science 393, 795–799 (2026).Article 
CAS 
PubMed 

Google Scholar 
Perera, U. C., Morgan, H. W. T., Hudson, E. R. & Derevianko, A. Host-dependent frequency offsets in 229Th nuclear clockwork. Phys. Rev. Lett. 135, 123001 (2025).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Zhang, C. et al. 229ThF4 thin films for solid-state nuclear clocks. Nature 636, 603–608 (2024).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Elwell, R. et al. Laser-based conversion electron Mössbauer spectroscopy of 229ThO2. Nature 648, 300–305 (2025).Article 
ADS 
CAS 
PubMed 
PubMed Central 

Google Scholar 
Morgan, H. W. T. et al. Proposal and theoretical investigation of 229Th-doped nonlinear optical crystals for compact solid-state clocks. Appl. Phys. Lett. 126, 111101 (2025).Article 
ADS 
CAS 

Google Scholar 
Trabs, P., Noack, F., Aleksandrovsky, A. S., Zaitsev, A. I. & Petrov, V. Generation of coherent radiation in the vacuum ultraviolet using randomly quasi-phase-matched strontium tetraborate. Opt. Lett. 41, 618–621 (2016).Article 
ADS 
CAS 
PubMed 

Google Scholar 
Lal, V. et al. Continuous-wave laser source at the 148 nm nuclear transition of Th-229. Optica 12, 1971–1974 (2025).Article 
ADS 
CAS 

Google Scholar 
Ooi, T. et al. Th-229 nuclear clock frequency record (JILA). Zenodo https://doi.org/10.5281/zenodo.15751158 (2025).Toscani De Col, L. et al. A thorium-229 optical nuclear clock with feedback loop. Nature https://doi.org/10.1038/s41586-026-11084-4 (2026).Morawetz, I. et al. Continuous-wave laser absorption spectroscopy of the Thorium-229 nucleus. Preprint at https://arxiv.org/abs/2604.16640 (2026).Lin, Y. et al. A 87Sr optical lattice clock with 2.9 × 10−17 uncertainty and its absolute frequency measurement. Metrologia 58, 035010 (2021).Article 
ADS 
CAS 

Google Scholar 
Chen, Z.-A. et al. A laser with instability reaching 4 × 10−17 based on a 10-cm-long silicon cavity at sub-5-K temperatures. Sci. Bull. 70, 3337–3344 (2025).Article 
CAS 

Google Scholar 
Kazakov, G. et al. Performance of a 229Thorium solid-state nuclear clock. New J. Phys. 14, 083019 (2012).Article 
ADS 

Google Scholar 
von der Wense, L. et al. The theory of direct laser excitation of nuclear transitions. Eur. Phys. J. A 56, 1–22 (2020).Article 
ADS 

Google Scholar 
Bjorklund, G. C., Levenson, M. D., Lenth, W. & Ortiz, C. Frequency modulation (FM) spectroscopy: theory of lineshapes and signal-to-noise analysis. Appl. Phys. B 32, 145–152 (1983).Article 
ADS 

Google Scholar 
Huang, B., Yan, G., Xiao, Q. & Bu, W. Data supporting “A nuclear clock synchronized to 229Th”. figshare https://doi.org/10.6084/m9.figshare.33386191 (2026).Download referencesAcknowledgementsWe thank J. Ye and C. Zhang for discussions, R. Yu, X. Feng, J. Yuan, F. Tang and R.-Q. Lei for assistance. S.D. thanks Q. Xue, W. Duan and H. Zhai for their support and co-ordination with crystal fabrication.FundingThis work is supported by Tsinghua University Dushi Program, Beijing Academy of Quantum Information Sciences (grant no. BAQISY25NG01), Beijing Science and Technology Planning Project (grant no. Z25110100040000) and the National Natural Science Foundation of China (grant nos. 12341401 and 12274253); the SIOM group is supported by Strategic Priority Research Program of the Chinese Academy of Sciences (grant no. XDB0920000), National Natural Science Foundation of China (grant nos. 12341404 and 12341402) and Zhangjiang Laboratory (grant no. ZJSP21A001D); the SICCAS group is supported by CAS Project for Young Scientists in Basic Research (grant no. YSBR-024); X.Z. acknowledges support from the Strategic Priority Research Program of the Chinese Academy of Sciences (grant no. XDB35020100) and the Quantum Science and Technology-National Science and Technology Major Project (grant no. 2021ZD0301903).Author informationAuthor notesThese authors contributed equally: Beichen Huang, Gaowei Yan, Qi Xiao, Wenhao Bu, Chengchun Zhao, Zhen Zhang, Chao YanAuthors and AffiliationsState Key Laboratory of Low-Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing, ChinaBeichen Huang, Gaowei Yan, Qi Xiao, Wenhao Bu, Gleb Penyazkov, Zhenhai Zhan, Lingfeng Yan, Ningyuan Ma, Juxian Li, Yanzhang Wu, Haoyu Shi, Yuxiang Mo, Li You & Shiqian DingBeijing Academy of Quantum Information Sciences, Beijing, ChinaBeichen Huang, Gaowei Yan, Qi Xiao, Wenhao Bu, Yuefei Wang, Xiangliang Li, Li You & Shiqian DingResearch Center of Laser Crystal, Advanced Laser and Optoelectronic Functional Materials Department, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai, ChinaChengchun Zhao, Peixiong Zhang, Lin Li, Shanming Li, Qiaorui Gong, Yuxiang Li & Yin HangCenter of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing, ChinaChengchun Zhao, Dapeng Jiang, Qiaorui Gong, Yuxiang Li & Yin HangState Key Laboratory of Functional Crystals and Devices, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai, ChinaZhen Zhang, Xiaobo Qian & Liangbi SuState Key Laboratory of Thorium Energy, Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai, ChinaChao Yan & Jun LinInternational Center for Quantum Materials, School of Physics, Peking University, Beijing, ChinaZhi-Ang Chen & Xibo ZhangBeijing Key Laboratory of Quantum Devices, Peking University, Beijing, ChinaZhi-Ang Chen & Xibo ZhangInstitute of Nuclear and New Energy Technology, Tsinghua University, Beijing, ChinaXuegang Liu, Qiange He & Taoxiang SunDivision of Time and Frequency Metrology, National Institute of Metrology, Beijing, ChinaHaochen Tian, Bingkun Lu & Yige LinHefei National Laboratory, Hefei, ChinaHaochen Tian, Li You, Yige Lin & Xibo ZhangState Key Laboratory of Precision Spectroscopy, East China Normal University, Shanghai, ChinaLongsheng MaNational Laboratory of Solid-State Microstructures, School of Physics, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing, ChinaShining ZhuFrontier Science Center for Quantum Information, Beijing, ChinaLi You & Shiqian DingAuthorsBeichen HuangView author publicationsSearch author on:PubMed Google ScholarGaowei YanView author publicationsSearch author on:PubMed Google ScholarQi XiaoView author publicationsSearch author on:PubMed Google ScholarWenhao BuView author publicationsSearch author on:PubMed Google ScholarChengchun ZhaoView author publicationsSearch author on:PubMed Google ScholarZhen ZhangView author publicationsSearch author on:PubMed Google ScholarChao YanView author publicationsSearch author on:PubMed Google ScholarZhi-Ang ChenView author publicationsSearch author on:PubMed Google ScholarPeixiong ZhangView author publicationsSearch author on:PubMed Google ScholarGleb PenyazkovView author publicationsSearch author on:PubMed Google ScholarZhenhai ZhanView author publicationsSearch author on:PubMed Google ScholarLingfeng YanView author publicationsSearch author on:PubMed Google ScholarYuefei WangView author publicationsSearch author on:PubMed Google ScholarLin LiView author publicationsSearch author on:PubMed Google ScholarShanming LiView author publicationsSearch author on:PubMed Google ScholarDapeng JiangView author publicationsSearch author on:PubMed Google ScholarXiaobo QianView author publicationsSearch author on:PubMed Google ScholarXuegang LiuView author publicationsSearch author on:PubMed Google ScholarQiange HeView author publicationsSearch author on:PubMed Google ScholarTaoxiang SunView author publicationsSearch author on:PubMed Google ScholarHaochen TianView author publicationsSearch author on:PubMed Google ScholarBingkun LuView author publicationsSearch author on:PubMed Google ScholarNingyuan MaView author publicationsSearch author on:PubMed Google ScholarJuxian LiView author publicationsSearch author on:PubMed Google ScholarYanzhang WuView author publicationsSearch author on:PubMed Google ScholarQiaorui GongView author publicationsSearch author on:PubMed Google ScholarYuxiang LiView author publicationsSearch author on:PubMed Google ScholarHaoyu ShiView author publicationsSearch author on:PubMed Google ScholarXiangliang LiView author publicationsSearch author on:PubMed Google ScholarLongsheng MaView author publicationsSearch author on:PubMed Google ScholarShining ZhuView author publicationsSearch author on:PubMed Google ScholarYuxiang MoView author publicationsSearch author on:PubMed Google ScholarJun LinView author publicationsSearch author on:PubMed Google ScholarLi YouView author publicationsSearch author on:PubMed Google ScholarYige LinView author publicationsSearch author on:PubMed Google ScholarXibo ZhangView author publicationsSearch author on:PubMed Google ScholarYin HangView author publicationsSearch author on:PubMed Google ScholarLiangbi SuView author publicationsSearch author on:PubMed Google ScholarShiqian DingView author publicationsSearch author on:PubMed Google ScholarContributionsB.H., G.Y., Q.X., W.B., G.P., Z. Zhan, L. Yan, Y. Wang, N.M., J. Li, Y. Wu and S.D. constructed the experimental setup and carried out the measurements. B.H., Q.X., Z. Zhang, C.Y., Z. Zhan, D.J., X.Q., X. Liu, Q.H., T.S., J. Lin, L.S. and S.D. fabricated and characterized the TS1 crystal. C.Z., P.Z., L.L., S.L., Q.G., Y. Li, L.M., S.Z. and Y.H. fabricated and characterized the S1 crystal. Z.-A.C. and X.Z. provided the ultrastable 1,397-nm laser referenced to the cryogenic silicon cavity. H.T., B.L. and Y. Lin provided the hydrogen maser. H.S., X. Li, Y.M. and L. You provided resources and contributed to discussions. S.D. conceived, initiated and supervised the project. B.H., Q.X. and S.D. wrote the manuscript with contributions from L. Yan and input from all authors.Corresponding authorsCorrespondence to
Wenhao Bu, Yin Hang, Liangbi Su or Shiqian Ding.Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature thanks Lars von der Wense and the other, anonymous, reviewer(s) for their contribution to the peer review of this work. Peer reviewer reports are available.
Additional informationPublisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.Extended data figures and tablesExtended Data Fig. 1 Broad pedestal accompanying line b in TS1.The main panel shows the full measured spectrum with a phenomenological double-Lorentzian fit over the full range (black dashed line), which captures the narrow component and broad pedestal, and, for comparison, a single-Lorentzian fit to the central data points within  ± 25kHz of the line centre (grey dashed line). Applying the same full-range double-Lorentzian analysis to lines a–d gives narrow-component FWHMs of 75(9), 26(1), 34(1) and 43(3) kHz, respectively, and corresponding pedestal FWHMs of 237(31), 334(44), 292(16) and 272(28) kHz. The inset reproduces the central data shown in Fig. 2b of the main text, together with a single-Lorentzian fit with a constant offset (blue dashed line). This fit yields a b-line linewidth of 27(1)kHz. The lower panel shows the residuals of the full-range double-Lorentzian fit.Extended Data Table 1 Frequency-modulation, lock-in-detection and feedback parameters for absorption spectroscopy and clock operationFull size tableSupplementary informationPeer Review File (download PDF )Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
Reprints and permissionsAbout this articleCite this articleHuang, B., Yan, G., Xiao, Q. et al. A nuclear clock synchronized to 229Th.
Nature (2026). https://doi.org/10.1038/s41586-026-11122-1Download citationReceived: 07 June 2026Accepted: 04 September 2026Published: 07 October 2026Version of record: 07 October 2026DOI: https://doi.org/10.1038/s41586-026-11122-1Share this articleAnyone you share the following link with will be able to read this content:Get shareable linkSorry, a shareable link is not currently available for this article.Copy shareable link to clipboard
Provided by the Springer Nature SharedIt content-sharing initiative

Download PDF

Associated content

A thorium-229 optical nuclear clock with feedback loop

L. Toscani De ColT. RiebnerT. Schumm

Nature
Article
Open Access
07 Oct 2026

Nuclear clocks tick for the first time

Akio Kawasaki

Nature
News & Views
07 Oct 2026

Advertisement

Explore content

Research articles

News

Opinion

Research Analysis

Careers

Books & Culture

Podcasts

Videos

Current issue

Browse issues

Collections

Subjects

Follow us on Facebook

Follow us on Bluesky

Follow us on X

Sign up for alerts

RSS feed

About the journal

Journal Staff

Research Cross-Journal Editorial Team

Editors

Journal Information

Journal Metrics

Our publishing models

Editorial Values Statement

Editorial policies

Journalistic Principles

History of Nature

Awards

Contact

Send a news tip

Publish with us

For Authors

For Referees

Language editing services

Open access funding

Submit manuscript

Search

Search articles by subject, keyword or author

Show results from

All journals
This journal

Search

Advanced search

Quick links

Explore articles by subject
Find a job
Guide to authors
Editorial policies

Nature

(Nature)

ISSN 1476-4687 (online)

ISSN 0028-0836 (print)

nature.com footer links

About Nature Portfolio

About us
Press releases
Press office
Contact us

Discover content

Journals A-Z
Articles by subject
protocols.io
Nature Index
Nature Books

Publishing policies

Nature portfolio policies
Open access

Author & Researcher services

Reprints & permissions
Research data
Language editing
Scientific editing
Nature Masterclasses
Research Solutions

Libraries & institutions

Librarian service & tools
Librarian portal
Open research
Recommend to library

Advertising & partnerships

Advertising
Partnerships & Services
Media kits

Branded
content

Professional development

Nature Awards
Nature Careers
Nature
Conferences

Regional websites

Nature Africa
Nature China
Nature India
Nature Japan
Nature Middle East

Privacy
Policy
Use
of cookies

Your privacy choices/Manage cookies

Legal
notice
Accessibility
statement
Terms & Conditions
Your US state privacy rights

© 2026 Springer Nature Limited

Close banner

Close

Sign up for the Nature Briefing newsletter — what matters in science, free to your inbox daily.

Email address

Sign up

I agree my information will be processed in accordance with the Nature and Springer Nature Limited Privacy Policy.

Close banner

Close

Get the most important science stories of the day, free in your inbox.
Sign up for Nature Briefing

The development of a nuclear clock synchronized to the 229Th isomer represents a practical pathway for creating compact, robust timekeeping and for conducting sensitive tests of fundamental physics by transferring the frequency reference from an electronic system to a nuclear transition. This approach leverages the unique property of the 229Th isomer, which has a transition energy in the vacuum-ultraviolet (VUV) range, making it directly addressable by current laser technology. The work achieved this by stabilizing a continuous-wave, narrow-linewidth 148.4 nm VUV laser to a resolved, weakly temperature-sensitive nuclear transition within 229Th:CaF2 crystals.

The experimental realization of this nuclear clock required integrating several technological components. A continuous-wave VUV source at 148.4 nm was generated through resonance-enhanced four-wave mixing in cadmium vapour. This VUV light was then coupled into a solid-state medium, specifically 229Th:CaF2 crystals, where spectroscopy was performed to resolve the nuclear structure. The investigation involved fluorescence and absorption spectroscopy to characterize the solid-state structure of the nuclear resonance, which revealed both quadrupole-unresolved (QU) and quadrupole-resolved (QR) structures, including clock-relevant transitions. The measurements yielded line widths for the QR components, such as 27 kilohertz for line b, which serves as the basis for clock operation.

To establish clock operation, the methodology integrated a system where the VUV probe was used for absorption spectroscopy to generate a nuclear discriminator. This involved modulating the VUV frequency and measuring the resulting change in the transmitted power, which functions as a dispersive error signal. This signal was fed back through an acousto-optic modulator to steer the VUV frequency onto the nuclear resonance for continuous feedback. The stability of the clock was then assessed by analyzing the cycle-by-cycle frequency record generated by this interrogation-and-feedback scheme, demonstrating that the laser inherited the stability from a cryogenic-silicon-cavity reference.

The study rigorously tested the reproducibility of the clock-transition frequency by comparing the results between two independently fabricated 229Th:CaF2 crystals. The frequency comparison between these crystals and external references, such as the JILA measurements for the thorium-229 transition, confirmed the reproducibility, showing a fractional frequency difference of approximately $2.8\times 10^{-13}$. The experimental setup included careful control of crystal temperature, which was found to introduce only negligible frequency fluctuations, ensuring the accuracy of the results.

Further analysis focused on minimizing measurement noise to achieve the highest precision. The noise contribution to the fractional frequency instability was analyzed, and methods were optimized to maximize the slope of the frequency discriminator. This optimization led to an increased sensitivity in the readout system, allowing for the detection of minute frequency fluctuations. The final optimized system achieved a fractional frequency instability of $5\times 10^{-13}/\sqrt{\tau/\text{s}}$, which is near the photon-shot-noise limit for the optimized configuration.

The study demonstrated that laser-addressed nuclei can serve as operational clock references and that 229Th:CaF2 provides a reproducible solid-state platform for such systems. This achievement is further supported by the capacity to characterize the depth-dependent excitation fraction within the crystal and to establish the relationship between the spectral properties and the resulting clock instability.