LmCast :: Stay tuned in

BIPM decides to stop adding leap seconds to UTC

Recorded: Oct. 16, 2026, 4:48 a.m.

Original Summarized

Resolution 5 (2026) - BIPM

Skip to Main Content

Sign in

Metrology areas

Quick links

français

Working together to promote and advance the global comparability of measurements

Menu

français

français

Home

About us

About us

Benefits of participation

Benefits of participation

Page Benefits of participation

Member States

Associates

How to join us

Governance

Governance

Page Governance

CIPM

CGPM

Founding documents

Strategy

Our Mission and Objectives

Our Mission and Objectives

Page Our Mission and Objectives

Our work programme

Knowledge transfer (CBKT)

Staff of the BIPM Headquarters

Jobs and opportunities

How to get to the BIPM

Historical information

Historical information

Page Historical information

Evolution of the SI

Metre Convention

Pavillon de Breteuil

CGPM (2026)

Coordination

Coordination

CIPM MRA

CIPM MRA

Page CIPM MRA

Participating laboratories

Use of the CIPM MRA logo

Documents on the CIPM MRA

CIPM MRA Comparison reports

CMC approval process

JCRB

KCDB >>

Help on the KCDB

CIPM Forums

CIPM Forums

Page CIPM Forums

Metrology and Digitalization

CIPM Consultative Committees

CIPM Consultative Committees

Page CIPM Consultative Committees

CCAUV

CCEM

CCL

CCM

CCPR

CCQM

CCRI

CCT

CCTF

CCU

Capacity Building and Knowledge transfer: CBKT

Guides in Metrology Committee: JCGM

Guides in Metrology Committee: JCGM

Page Guides in Metrology Committee: JCGM

JCGM-WG1 (GUM)

JCGM-WG2 (VIM)

International reference time scales

International reference time scales

Page International reference time scales

Time FTP Server

Time Department Database

Laboratory medicine: JCTLM

Laboratory medicine: JCTLM

Page Laboratory medicine: JCTLM

JCTLM Database >>

JCTLM portal >>

Liaison

Liaison

Institutional liaisons

Institutional liaisons

Page Institutional liaisons

Alphabetical list

Formal agreements

Digital transformation

Quality infrastructure

Technical liaisons

CODATA-TGFC

Joint Committees

Joint Committees

Page Joint Committees

Guides in Metrology Committee: JCGM

Laboratory medicine: JCTLM

CIPM MRA: JCRB

NMI Directors and Member State Representatives

Regional metrology organizations

Regional metrology organizations

Page Regional metrology organizations

AFRIMETS

APMP

COOMET

EURAMET

GULFMET

SIM

Toolbox

Technical/Scientific

Technical/Scientific

The SI

The SI

Page The SI

Defining constants

SI base units

SI prefixes

Practical realizations

SI Brochure

SI promotion

Redefinition of the second

Technical areas of the BIPM

Technical areas of the BIPM

Page Technical areas of the BIPM

Electrical metrology

Gas metrology

Mass metrology

Organic analysis

Radiation dosimetry

Radionuclide metrology

Time metrology

Publications & Events

Publications & Events

Publications

Publications

Page Publications

Annual Review

CGPM: Proceedings

CIPM: Publications

CIPM MRA Comparison reports

Documents on the CIPM MRA

Financial Report

Guides in Metrology (GUM and VIM)

Metrologia

Monographies BIPM

Practical realizations

Notification

Rapports BIPM

Scientific output

SI Brochure

Standard frequencies

Time scales and related data

Metrology resources

Metrology resources

Page Metrology resources

SI Digital Framework

e-Learning Platform >>

Impact Studies

Common terms

JCTLM Database >>

KCDB - CIPM MRA Database

Metrology in the fight against Covid-19

Time scales - BIPM FTP server

Time Department Database

Events

Events

Page Events

Upcoming

28th meeting of the CGPM (2026)

BIPM and co-organized workshops

World Metrology Day

150th anniversary

External events

Metrology areas

AUV: Acoustics, Ultrasound and Vibrations

CCAUV

BIPM contact: Dr Gianna Panfilo

EM : Electricity and Magnetism

Metrologia: Focus on Metrology in Electricity and Magnetism

CCEM

BIPM contact: Dr Michael Stock

L: Length

CCL

BIPM contact: Dr Gianna Panfilo

M: Mass and related quantities

CCM

BIPM contact: Dr Hao Fang

PR: Photometry and Radiometry

QM: Chemistry and Biology

People

RI: Ionizing radiation

T: Thermometry

TF: Time and Frequency

CCTF

BIPM Time Department Database

Time FTP Server

BIPM contact: Dr Patrizia Tavella

U

CCU

Metrology areas

Quick links

Sign in

Metrology areas

Quick links

français

Sign in

Sign In

Authentication failed. Please enable browser cookies and try again.

Sign In


Email Address


Password

Caps Lock is on.

Sign In

Password forgotten

Sign in

Metrology areas

Quick links

français

Metrology areas

AUV: Acoustics, Ultrasound and Vibrations

CCAUV

BIPM contact: Dr Gianna Panfilo

EM : Electricity and Magnetism

Metrologia: Focus on Metrology in Electricity and Magnetism

CCEM

BIPM contact: Dr Michael Stock

L: Length

CCL

BIPM contact: Dr Gianna Panfilo

M: Mass and related quantities

CCM

BIPM contact: Dr Hao Fang

PR: Photometry and Radiometry

QM: Chemistry and Biology

People

RI: Ionizing radiation

T: Thermometry

TF: Time and Frequency

CCTF

BIPM Time Department Database

Time FTP Server

BIPM contact: Dr Patrizia Tavella

U

CCU

Sign in

Metrology areas

Quick links

français

Quick links

The 2018 revision of the SI

Celebrating the vote by the CGPM

26th CGPM (November 2018)

2018 values of the Fundamental Physical Constants

Resolution 1 of the 26th CGPM (2018)

SI Brochure (2019)

World Metrology Day

International Vocabulary of Metrology (VIM)

Metrologia

Guide to the Expression of Uncertainty in Measurement

Autres publications

Resolutions of the CGPM

Time FTP Server

Capacity Broadening & Knowledge Transfer (CBKT)

NMI Directors and Member State Representatives

BIPM strategy document

Toolbox: Benefits and how to participate

JCRB

tests

Test URL

KCDB

Resolution 5 (2026)

Resolution-CGPM-28-5

Resolution 5 of the 28th CGPM
(2026)

On the technical actions needed to ensure the continuity of UTC

The General Conference on Weights and Measures (CGPM), at its 28th meeting,
recalling that
the CGPM, when adopting Resolution 2 “On the definition of time scales” at its 26th meeting (2018),
confirmed that Coordinated Universal Time (UTC) is a time scale produced by the International Bureau of Weights and Measures (BIPM) with the same rate as International Atomic Time (TAI), but differing from TAI only by an integral number of seconds,
stated that UTC is the only recommended time scale for international reference and the basis of civil time in most countries,
the CGPM, when adopting Resolution 4 “On the use and future development of UTC” at its 27th meeting (2022),
recalled that the offset by an integral number of seconds is due to the agreement maintained between UTC and the time scale describing the angular rotation of the Earth (UT1),
decided that the maximum value for the difference |UT1-UTC| will be increased in, or before, 2035, to ensure the continuity of UTC for at least a century,
requested the CIPM to draft a resolution for the 28th meeting of the CGPM (2026),

recognizing that
industrial users and the synchronization needs of national critical infrastructures, for example transportation, energy distribution, telecommunication, and space projects require UTC to be continuous without any future adjustment,
for some applications it is necessary to fix a maximum value for the difference |UT1-UTC| to appropriately design the software underlying operational systems,
in many countries there are differences of more than one hour between local apparent solar time and civil time due to the choice of time zone, and changes of an hour are regularly introduced when daylight-saving time is used,
further recognizing that
users of UT1 can find information on the value of the difference UT1-UTC in the Global Navigation Satellite Services (GNSS) navigation messages, and internet services provided by the International Earth Rotation and Reference Systems Service (IERS), National Metrology Institutes (NMIs), and other services,
the International Telecommunication Union Radiocommunication Sector (ITU-R), through its Working Party 7A, is studying possible updates of the code for the transmission of the difference UT1-UTC by radio stations and Resolution 655 (REV.WRC-23) resolved to “establish a transition period for implementation and allow for the possibility to disseminate the increased difference between UT1 and UTC via radiocommunication system until 2035, but no later than 2040, in cases where existing equipment cannot be replaced earlier”,
noting that
a workshop organized by the Consultative Committee for Time and Frequency (CCTF) and IERS in March 2025, which included experts on Earth rotation, estimated that the probability of a negative leap second will increase rapidly in the near future, reaching a 30 % probability by 2035,
a negative leap second has not previously been applied, and it is considered to pose a high risk of causing anomalies and disruption to critical infrastructures that are largely unprepared, and the preparation would create, for the industries that rely on time synchronization, a need for financial investment, whose amount is estimated to be similar to their preparations for the millennium bug,
the growing influence of IoT (Internet of Things) technologies, dispersed multi-sensor systems, smart grids, and virtual services for contemporary society, creates an increasing risk of malfunction in operation of systems and services with the insertion of any leap second, especially with a negative one,
the use of different mitigation methods for leap second introductions by global service providers in their server systems, in order to avoid time steps, leads to inconsistency in timing between different systems and in the disseminated time and frequency, which do not conform to the SI unit,
international organizations including the International Telecommunication Union Telecommunication Standardization Sector (ITU-T), the International Union of Radio Science (URSI), international working groups such as the Institute of Electrical and Electronics Engineers (IEEE) 1588, and individual industry representatives have provided formal statements to the BIPM on the need to bring forward the implementation of UTC as a continuous time scale to avoid the risk of the insertion of a negative leap second,
the additional risk of a delay in updating UTC could cause some user organizations to change their reference time scales to, for example, a GNSS time instead of UTC, seriously compromising the concept of international standardization in metrology,
welcoming
the excellent collaboration between the BIPM and the ITU-R and the endorsement of CGPM Resolution 4 (2022) at the World Radiocommunication Conference by Resolution 655 (REV.WRC 2023),
the support and engagement of the IERS to take all necessary measures to change its operational provision for, and its announcement of, leap seconds according to the CGPM resolutions,
decides that
continuous UTC will become effective on 20 May 2027,
the maximum value for the difference |UT1-UTC| will be 3 600 seconds (1 hour), ensuring the long term continuity for UTC for several centuries,
requests the BIPM
to continue to collaborate with the International Telecommunication Union (ITU), International Astronomical Union (IAU), International Union of Geodesy and Geophysics (IUGG), IERS, and other organizations that may be impacted by this decision in order to
inform users and support the application of this decision,
continue to monitor the value of UT1-UTC, its estimated evolution and modelling as determined by the IERS,
inform the CIPM regularly on the evolution of the value of UT1-UTC,
and to continue to work with the Regional Metrology Organizations, the NMIs, and users to promote the understanding of the importance of a continuous UTC and its prompt and efficient provision to the users.

https://www.doi.org/10.59161/CGPM2026RES5E

The reader should note that the official version of this Resolution is the French
text

CGPM logo

Menu Display

Resolution 1 (2026)

Resolution 2 (2026)

Resolution 3 (2026)

Resolution 4 (2026)

Resolution 5 (2026)

Resolution 6 (2026)

Resolution 7 (2026)

View

Hidden

Contact

Access

Sitemap

Copyright

Confidentiality

Quick links

français

Bipm e-news

LinkedIn

YouTube

Pavillon de Breteuil
F-92312 Sèvres Cedex FRANCE
Copyright @ BIPM tous droits réservés

We use cookies to optimize our website. View privacy policy

Accept

Resolution 5 of the 28th General Conference on Weights and Measures (CGPM) of 2026 outlines the technical actions required to maintain the continuity of Coordinated Universal Time (UTC). The resolution recalls previous decisions, specifically Resolution 2 from the 26th CGPM (2018) regarding the definition of time scales, and Resolution 4 from the 27th CGPM (2022) concerning the use and future development of UTC. It establishes that UTC is the sole recommended time scale for international reference and forms the basis for civil time in most nations. The resolution clarifies that the observed difference between UTC and the time scale describing the Earth's angular rotation (UT1) stems from the agreement maintained between UTC and UT1.

The CGPM decided that to ensure the continuity of UTC for at least a century, the maximum permissible difference between UT1 and UTC will be increased or set, with a maximum value fixed at 3600 seconds, or one hour. This measure is critical for industrial users and the synchronization needs of national critical infrastructures, such as transportation, energy distribution, telecommunication, and space projects, which require uninterrupted UTC without future adjustments. Furthermore, the resolution recognizes that achieving this continuity necessitates addressing the practical implications of time zone changes and daylight saving time adjustments, which introduce hourly differences between local apparent solar time and civil time in many regions.

The resolution addresses the increasing risk associated with leap seconds, noting that experts from the Consultative Committee for Time and Frequency (CCTF) and the International Earth Rotation and Reference Systems Service (IERS) estimated that the probability of a negative leap second will increase rapidly, reaching 30 percent probability by 2035. The introduction of a negative leap second poses a significant risk of causing anomalies and disruptions to critical infrastructures because these systems are largely unprepared for such events, requiring substantial financial investment similar to that prepared for the millennium bug. This risk is amplified by the growing influence of Internet of Things (IoT) technologies, dispersed multi-sensor systems, smart grids, and virtual services, where any time step, especially a negative one, introduces inconsistencies in timing across different systems and frequency dissemination that do not conform to the SI unit.

International bodies, including the International Telecommunication Union (ITU-T), the Union of Radio Science (URSI), and various engineering working groups such as IEEE 1588, have formally urged the BIPM to prioritize the implementation of continuous UTC to avoid the risk of a negative leap second. Delaying updates to UTC could lead some user organizations to shift their reference time scales, such as using GNSS time instead of UTC, thereby compromising the fundamental principles of international metrological standardization.

In response, the resolution mandates that continuous UTC will become effective on May 20, 2027. The BIPM is requested to continue collaboration with key international organizations, including the International Telecommunication Union (ITU), the International Astronomical Union (IAU), the International Union of Geodesy and Geophysics (IUGG), IERS, and other relevant entities, to inform users and support the application of this decision. Specifically, the BIPM must continue to monitor the evolution of the UT1-UTC difference, its estimated changes and modeling provided by the IERS, and regularly inform the CIPM about this evolution. Additionally, the BIPM is tasked with working with Regional Metrology Organizations, National Metrology Institutes (NMIs), and end-users to foster an understanding of the necessity for continuous UTC and its prompt and efficient provision.